firezone
party wall system
Firezone - FRL 60/60/60 Intertenancy Wall System
- FRL 60/60/60 intertenancy (party) wall performance
- Designed for timber and light‑gauge steel frames
- Eliminates unnecessary components and accessories
- Faster, cleaner installation
- Clear detailing and documentation
- CodeMark certified for compliance confidence
- No mould or moisture issues
- Meets a minimum of Rw+Ctr=50dB

- Townhouses and duplexes
- Multi‑residential intertenancy walls
- Low‑rise apartments
- Dual‑occupancy developments
- Medium‑density projects where FRL 60/60/60 is required
Firezone has been designed to offer a simple and more secure party wall system whilst being less afffected by the weather, meaning less replacement product, mould or rectification work.
CBMA Firezone is the perfect party wall system. Designed to provide a simple and effective fire rated party wall system, Firezone is also weather, mould and impact resistant, making it a premium product for a party wall system saving costs and time on site.
Firezone has been designed for many applications including:
Townhouse | Apartments | Multi-residential | Dual lock ups
Properties |
Specification |
Notes |
Standard |
|---|---|---|---|
| Dimensions – Overall Coverage |
2700mm x 600mm x 22mm | Width / Length: +/- 1.5mm | AS2908.2 |
| Profile | Shiplap – all edges | ||
| Characteristics | Pink in colour | ||
| Panel Layout | Horizontal + Vertical install pattern | ||
| Weight (Approx) | 26.5kg/m2 | ||
| Modulus of rupture (Wet) | 7.5MPa | AS2908.2 | |
| Wall Cavity | 20mm – 40mm each side of Firezone | ||
| Frame Type | Timber or Steel | AS1684 / AS4600 | |
| Total Wall Thickness (min.) | 262mm (nom.) |
Firezone has been tested and certified by independent industry professionals including NATA accredited laboratories. Firezone has been accredited with CodeMark certification.
Properties |
Result |
Standard |
|---|---|---|
| Fire Rating Level | FRL 60/60/60 | AS1530.4 |
| Combustibility | Pass as non-combustible | AS1530.1 |
| Thermal | Rt(summer) 4.7m2K/W and Rt(winter)5.0K/W (timber frame) | AS/NZS4859.1 |
| Acoustic | Rw+Ctr = 50dB – (7.9kg/m2 plasterboard + R2.5 insulation) | AS1191-2002 |
What FRL rating does Firezone achieve?
Can Firezone be used with steel framing?
How is Firezone different from typical shaftliner or masonry systems?
Do I need specialty installers or tools?
No. Standard trades can install Firezone using common framing and tools when following the installation guide, saving multiple trades.